HC-M-02-AT-M-25 - HC-M-02-AT-M-25 1421377 PHOENIX CONTACT Module inserts contact HC-M-02-AT-M-25 1421377
اسٹاک میں ہاٹ پروڈکٹ

HC-M-02-AT-M-25

HC-M-02-AT-M-25 1421377 PHOENIX CONTACT Module inserts contact HC-M-02-AT-M-25 1421377

$0.00امریکی ڈالر
3215 اسٹاک میں
اہم وضاحتیں
:Note regarding axial connection technology:Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.Cables with a geometric cross section which deviates significantly from the nominal cable cross section must be checked before use.The axial connection technology connection space is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) must be checked before use.Assembly instructionsBefore assembly, ensure that the tapered screw is fully loosened (chamber is open). Cables must not be twisted. The wires must be pushed into the contact chamber as far as they will go (until the insulation touches the contact). Hold the wires in position and tighten using an Allen key. The used wire end must be cut off before reconnection. The terminal screw must only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable must be mechanically held at an appropriate distance from the connection point (e.g., when used in a plate cut out). For notes on correct execution, see DIN VDE 0100-520:2003-06. Unused connections must be tightened with maximum torque.
جنرل:For HEAVYCON HC-B6 to B48 housing, snap-in module frame required, axial connection for 4 mm Allen key
درخواست:Power
شرح شدہ کرنٹ:100 A
سپلائر کی معلومات
پروڈکٹس: 0
عام طور پر 2-3 کاروباری دنوں میں بھیج دیا جاتا ہے
کوالٹی کی ضمانت
تیز شپنگ
تکنیکی معاونت

تکنیکی تفصیلات

پیرامیٹرقیمت
Note regarding axial connection technology:Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.Cables with a geometric cross section which deviates significantly from the nominal cable cross section must be checked before use.The axial connection technology connection space is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) must be checked before use.Assembly instructionsBefore assembly, ensure that the tapered screw is fully loosened (chamber is open). Cables must not be twisted. The wires must be pushed into the contact chamber as far as they will go (until the insulation touches the contact). Hold the wires in position and tighten using an Allen key. The used wire end must be cut off before reconnection. The terminal screw must only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable must be mechanically held at an appropriate distance from the connection point (e.g., when used in a plate cut out). For notes on correct execution, see DIN VDE 0100-520:2003-06. Unused connections must be tightened with maximum torque.
جنرلFor HEAVYCON HC-B6 to B48 housing, snap-in module frame required, axial connection for 4 mm Allen key
درخواستPower
شرح شدہ کرنٹ100 A
آلودگی کی ڈگری3
عہدوں کی تعداد2
شرح شدہ سرج وولٹیج8 kV
اوور وولٹیج کیٹیگریIII
اسمبلی کی ہدایاتTo ensure correct use, installation in housing with IP54 protection or better is required
شرح شدہ وولٹیج (III/3)1000 V
UL 94 کے مطابق آتش گیر درجہ بندیV0
انفرادی تار کی سٹرپنگ لمبائی13 mm

پروڈکٹ کی وضاحت

Contact insert module, Pin, Axial screw connection, 1000 V, 100 A, 10 mm2 ... 25 mm2, application: Power