Soft Start Three-Phase Scroll Compressors 32 A; 3 controlled phases;High Pressure Start-Up; 45 mm
اہم خصوصیات
  • صنعتی معیار
  • RoHS کے مطابق
  • سی ای سرٹیفائیڈ
  • 1 سال کی وارنٹی

تکنیکی تفصیلات

Soft StarterThree-Phase Scroll Compressor Soft StarterTypes RSBD, RSBTProduct Description• Soft starting of 3-phase scroll compressors up to 45Amp• Patented auto-adaptive algorithm for optimum inrush current reduction (No user settings required)• 2- (RSBD) and 3-Phase (RSBT) controlled solutions• Current balancing strategy (RSBD models)• Integrated bypass relays• Internally supplied• Short ramp up time: <600ms• Rated operational voltage: 220VAC, 400VACrms, 50/60Hz• Rated operational current: 121, 16, 25, 32, 371, 451AAC• Over-temperature, Overcurrent, Locked Rotor protection• cULus, CE, RoHS compliant, CCC1• HP version for multi-compressor systems• VDE approved (Up to 32AAC) - for RSBT...HPV modelsNote: Other models (RSBT) only VDE approved up to 15ArmsOrdering Key RSB T40 16 EV 11 H P VRSBD and RSBT are easy to use soft starters for scroll compressors up to 45Amp (RSBD) and 32Amp (RSBT) nominal current. The units are equipped with a patented auto-adaptive algorithm that automatically adapts itself to the specific compressor it is controlling ensuring that an optimum inrush current reduction is achieved.Type SelectionRSBD is a 2-phase controlled solutionandRSBT isa3- phase controlled solution. RSBD and RSBT are internally bypassed resulting in less heat dissipation inside the panel.Short Circuit and Overload protectionare notprovided with the controller and must be procured separately.Compressor Soft Starter Controlled Phases Operational VoltageRated Operational CurrentControl VoltageVersionOptimised algorithm for multi-compressor systems and high pressure startsVDE approved versions (up to 32Arms)2TypeOperational Voltage Ue Rated OperationalCurrent Ie @ 40°CControl Voltage UcVersionRSBD2-Controlled phasesRSBT3-Controlled phases40: 220 – 400 VAC+10% -15%22: 220VAC, +10% -15%40: 400VAC, +10% -15%12: 12 Arms116: 16 Arms25: 25 Arms32: 32 Arms37: 37 Arms150: 45 Arms1E: 110 – 400 VAC+10% -15%F1: 24VAC/DC+10% -15%V11:DIN Mount2V21:DIN Mount & RFPMV00 module ready mounted2V51:DIN Mount (UL approved)2V61:DIN Mount & RFPMV00 module ready mounted(UL approved)2V..HP: Optimised algorithm for multi-compressor systems & high pressure startsV.HPV: VDE approved (up to 32AAC)TypeOperationalVoltageOperationalCurrentControlVoltageVersions HP Algorithm VDE Approved(up to 32Arms)[RSBD][40]121625E V51HP32F V613750[RSBT]1 Applies to RSBD40 models only2 Applies to RSBT.. HPV models only[22] [40]1625E32V11V61V11V21V51V61HPVOptionsSpecifications are subject to change without notice (20.11.2014) 1

پروڈکٹ دستاویزات

ڈیٹا شیٹ

تکنیکی تفصیلات اور کارکردگی کے ڈیٹا

یوزر مینول

انسٹالیشن اور آپریشن گائیڈ

Top