| پیرامیٹر | قیمت |
|---|---|
| آئٹم | Specifications |
| پی ایف ایچ ڈی | 2.4 × 10-9(Note) Probability of dangerous failure per hour. |
| کیبل | 0.15 mm2(power line: 0.2 mm2) 12-core heat-resistant PVC cable with connector, 0.5 m 1.640 ft long |
| ایم ٹی ٹی ایف ڈی | 100 years or more(Note) Mean time to dangerous failure. |
| تفصیلات | Min. sensing object ø25 mm ø0.984 in (20 mm 0.787 in beam pitch) |
| پروڈکٹ | Compact Safety Light Curtain[Type4 PLe SIL3] |
| مواد | Enclosure: Polycarbonate |
| بیم پچ | 20 mm0.787 in |
| لوازمات | SF4B-TR25 (Test rod): 1 pc. |
| پارٹ نمبر | SF4B-H20CA-J05 |
| پروڈکٹ کا نام | Compact Safety Light Curtain[Type4 PLe SIL3] SF4B-C |
| ELCA فنکشن | Incorporated (reducing mutual interference automatically) |
| پاور وولٹیج | 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
| جوابی وقت | OFF response: 14 ms or lessON response: 80 to 90 ms |
| پروڈکٹ نمبر | SF4B-H20CA-J05 |
| کیبل کی توسیع | Extension up to total 50 m164.042 ftis possible for both emitter and receiver optional mating cables |
| فنکشن کو خاموش کرنا | Incorporated |
| آپریٹنگ رینج | 0.3 to 7m0.984 to 22.966 ft(Note) The operating range is the possible setting distance between the emitter and the receiver. |
| خارج کرنے والا عنصر | Infrared LED (Peak emission wavelength: 850 nm0.033 mil) |
| آلودگی کی ڈگری | 3 |
| اوور رائڈ فنکشن | Incorporated |
| حفاظتی اونچائی | 423.4 mm 16.669 in |
| انٹرلاک فنکشن | Incorporated [Manual reset / Auto reset](Note) The manual reset and automatic reset are possible to be switched depending on the wiring status. |
| آپریٹنگ اونچائی | 2,000 m6,561.68 ftor less(Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m. |
| اختیاری افعال | Muting setting changing, override setting changing, fixed blanking, floating blanking, light emitting amount control, auxiliary output switching, protecting, interlock setting changing, external relay monitor setting changing(Note) In case of using optional function, the handy-controller SFB-HC is required. |
| محیطی روشنی | Incandescent light: 3,500 liter x or less at the light-receiving face |
| کم از کم سینسنگ آبجیکٹ | ø25 mm ø0.984 in opaque object(Note) In case the blanking function is valid, the operation mode is changed. |
| بیم چینلز کی تعداد | 20 |
| اخراج کو روکنے کا فنکشن | Incorporated |
| معاون آؤٹ پٹ کو خاموش کرنا | NPN open-collector transistor• Maximum sink current: 100 mA• Applied voltage: Same as supply voltage (between the muting auxiliary output and 0 V)• Residual voltage: 2.5 V or less (sink current 100 mA, when using 20 m65.617 ftlength cable) |
| مؤثر یپرچر زاویہ | plus or minus 2.5℃ or less [for an operating range exceeding 3 m9.843 ft(conforming to IEC 61496-2 / ANSI/UL 61496-2) ] |
| قابل اطلاق معیارات: جاپان | JIS B 9704-1 / 2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508-1 to 3 (SIL3) |
| قابل اطلاق معیار: یورپ | EN 61496-1 (Type 4), EN ISO 13849-1:2015 (Category 4, PLe), EN 61508-1 to 3 (SIL3), EN 55011, EN 50178, EN 61000-6-2(Note) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate. |
| کنٹرول آؤٹ پٹس (OSSD 1، OSSD 2) | PNP open-collector transistor / NPN open-collector transistor (switching method)• Maximum source current: 200 mA• Applied voltage: Same as supply voltage (between the control output and +V)• Residual voltage: 2.5 V or less (source current 200 mA, when using 20 m65.617 ftlength cable)• Leakage current: 0.1 mA or less (Including power supply OFF condition)• Maximum load capacity: 0.22 micro F (No load to maximum output current)• Load wiring resistance: 3Ωor less• Maximum sink current: 200 mA• Applied voltage: Same as supply voltage (between the control output and 0 V)• Residual voltage: 2.5 V or less (sink current 200 mA, when using 20 m65.617 ftlength cable)• Leakage current: 0.1 mA or less (Including power supply OFF condition)• Maximum load capacity: : 0.22 micro F (No load to maximum output current)• Load wiring resistance: 3Ωor less |
| قابل اطلاق معیارات: شمالی امریکہ | ANSI / UL 61496-1 / 2 (Type 4), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 4), CAN / CSA C22.2 No.14, OSHA 1910.212, OSHA 1910.217 (C), ANSI B11.1 to B11.19, ANSI / RIA 15.06(Note) With regards to the standards in the US/Canada, a Notified Body, TÜV SÜD, has certified the CTÜVUS mark. |
| بیرونی آلہ کی نگرانی کی تقریب | Incorporated |
| معاون پیداوار (غیر حفاظتی پیداوار) | PNP open-collector transistor / NPN open-collector transistor (switching method)• Maximum source current: 60 mA• Applied voltage: Same as supply voltage (between the auxiliary output and +V)• Residual voltage: 2.5 V or less (source current 60 mA, when using 20 m65.617 ftlength cable)• Maximum sink current: 60 mA• Applied voltage: Same as supply voltage (between the auxiliary output and 0 V)• Residual voltage: 2.5 V or less (sink current 60 mA, when using 20 m65.617 ftlength cable) |
| بڑے کثیر مقصدی اشارے کی تقریب | Incorporated |
| معاون آؤٹ پٹ کو خاموش کرنا: آپریشن موڈ | When muting auxiliary output: ON |
| قابل اطلاق ضوابط اور سرٹیفیکیشن | CE Marking (Machinery Directive, EMC Directive, RoHS Directive), UKCA Marking [Supply of Machinery (Safety) Regulations, EMC Regulations, RoHS Regulations], TÜV SÜD certification |
| ماحولیاتی مزاحمت: محیطی نمی | 30 to 85 % RH, Storage: 30 to 85 % RH |
| ماحولیاتی مزاحمت: جھٹکا مزاحمت | 300 m / s2acceleration (30 G approx.) in X, Y and Z directions for three times each |
| معاون آؤٹ پٹ کو خاموش کرنا: پروٹیکشن سرکٹ | Incorporated |
| خالص وزن (ایمیٹر اور وصول کنندہ کا کل) | approx. 520 g |
| قابل اطلاق معیار: بین الاقوامی معیار | IEC 61496-1 / 2 (Type 4), ISO 13849-1:2015 (Category 4, PLe), IEC 61508-1 to 3 (SIL3) |
| ماحولیاتی مزاحمت: محیطی درجہ حرارت | -10 to +55℃+14 to +131 ℉(No dew condensation or icing allowed), Storage: –25 to +60 ℃–3 to +140 ℉ |
| ماحولیاتی مزاحمت: تحفظ کی ڈگری | IP65 (IEC) |
| ماحولیاتی مزاحمت: کمپن مزاحمت | 10 to 55 Hz frequency, 0.75 mm0.030 inamplitude in X, Y and Z directions for two hours each |
| ماحولیاتی مزاحمت: موصلیت مزاحمت | 20 MΩ or more, with 500 V DC megger between all supply terminals connected together and enclosure |
| کنٹرول آؤٹ پٹس (OSSD 1، OSSD 2): آپریشن موڈ | ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal)(Note) During muting, control output will not turn off even if the beams are interrupted.(Note) When the blanking function is enabled, the operating mode will change. |
| کنٹرول آؤٹ پٹس (OSSD1، OSSD2): پروٹیکشن سرکٹ | Incorporated |
| ماحولیاتی مزاحمت: وولٹیج کے خلاف مزاحمت | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
| معاون پیداوار (نان سیفٹی آؤٹ پٹ): آپریشن موڈ | OFF when control outputs are ON, ON when control outputs are OFF (Factory setting, operating mode can be changed using the SFB-HC handy-controller.) |
| معاون پیداوار (نان سیفٹی آؤٹ پٹ): پروٹیکشن سرکٹ | Incorporated |
| موجودہ کھپت: بڑے کثیر مقصدی اشارے کو روشن کرتا ہے۔ | Emitter: 75 mA or lessReceiver: 85 mA or less |
| موجودہ کھپت: بڑے کثیر مقصدی اشارے کی لائٹس بند | Emitter: 65 mA or lessReceiver: 75 mA or less |
تکنیکی تفصیلات اور کارکردگی کے ڈیٹا
انسٹالیشن اور آپریشن گائیڈ