| پیرامیٹر | قیمت |
|---|---|
| آئٹم | Specifications |
| پی ایف ایچ ڈی | 2.07×10-9 |
| ایم ٹی ٹی ایف ڈی | 582 years or more |
| تبصرہ | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃+68 ℉.PFHD: Probability of Dangerous Failure per Hour, MTTFD: Mean Time to Dangerous Failure (in years). |
| تفصیلات | Min. sensing object ø14 mmø0.551 in(10 mm0.394 inbeam pitch) |
| پروڈکٹ | Safety Light Curtain [Type 4 PLe SIL3] |
| مواد | Enclosure : Aluminum, Detection surface : Polycarbonate resin and stainless steel (SUS304), Upper cap / lower cap : Nylon |
| لوازمات | SF4B-TR14 (test rod) : 1 pc. |
| پارٹ نمبر | SF4D-F39 |
| پروڈکٹ کا نام | Compact & Robust Safety Light Curtain [Type 4 PLe SIL3] SF4D |
| حفاظت کی حالت | Control output (OSSD 1 / 2) OFF state |
| پاور وولٹیج | 24 V DC+20-30 %Ripple P-P 10 % or less (excluding voltage drop due to cable)(Note): In consideration of the voltage drop caused by the cable, use Control output (OSSD 1, OSSD 2) source / sink current and cable length as a guideline. |
| پروڈکٹ نمبر | SF4D-F39 |
| سب سسٹم کی قسم | Type B (IEC 61508-2) |
| کیبل کی توسیع | Total length of emitter / receiver can be extended up to 70 m229.659 fteach using optional mating cable (including the lengthof series mating cables)(Note): In consideration of the voltage drop caused by the cable, use Control output (OSSD 1, OSSD 2) source / sink current and cable length as a guideline. |
| فنکشن کو خاموش کرنا | Incorporated (12-core cable) |
| آپریٹنگ رینج | Short mode : 0.2 to 7 m0.656 to 22.966 ftLong mode : 0.8 to 12 m2.625 to 39.370 ft(selectable by DIP switch)(Note): The operating range is the possible setting distance between the emitter and the receiver. |
| خارج کرنے والا عنصر | Infrared LED (peak emission wavelength : 850 nm0.0335 mil) |
| آلودگی کی ڈگری | 3 |
| جڑنے کا طریقہ | By connector |
| اوور رائڈ فنکشن | Incorporated (12-core cable) |
| حفاظتی اونچائی | 390 mm15.354 in(Note): When using as a safety device for a press machine in China, the length from the center of the first beam channel to the center of the last beam channel become to be protective height. |
| انٹرلاک فنکشن | Incorporated [Manual reset / auto reset (selectable by wiring)] (8-core cable or 12-core cable) |
| آپریٹنگ اونچائی | 2,000 m6,561.68 ftor less(Note): Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m. |
| اختیاری افعال | Fixed blanking function, floating blanking function, interlock setting function, external device monitoring setting function, auxiliary output settingfunction, application indicator setting function, muting setting function, override setting function, protect function, cable switching function(Note): To use optional functions, the SF4D-TM1 (optional) and Configurator Light Curtain setting software are required. |
| محیطی روشنی | Incandescent light : 5,000 ℓx or less at the light-receiving surface |
| موجودہ کھپت | Emitter : 120 mA or lessReceiver : 140 mA or less |
| کم از کم سینسنگ آبجیکٹ | ø14 mmø0.551 inopaque object(Note): When the floating blanking function is used, the size of the minimum sensing object varies. For the detail, refer to the section on Safety distance. |
| پاور سیف فنکشن | Incorporated |
| ٹیسٹ ان پٹ فنکشن | Incorporated |
| بیم چینلز کی تعداد | 39 |
| ناکامی کے جواب کا وقت | Within response time (OFF response) |
| ہم وقت سازی کا طریقہ | Line synchronization / optical synchronization (selectable by DIP switch) |
| مؤثر یپرچر زاویہ | ±2.5° or less at a sensing range of 3 m9.843 ftor longer (based on IEC 61496-2) |
| لاک آؤٹ ریلیز فنکشن | Incorporated |
| T1 (ثبوت ٹیسٹ وقفہ) | 20 years |
| قابل اطلاق معیار: چین | GB/T 4584 |
| قابل اطلاق معیارات: جاپان | JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508-1 to 3 (SIL3) |
| قابل اطلاق معیار: یورپ | EN ISO 13849-1:2015 (Category 4, PLe), EN 55011, EN 61000-6-2, EN IEC 63000 |
| SFF (محفوظ ناکامی کا حصہ) | 99% |
| ایپلیکیشن اشارے کی تقریب | Incorporated (only the receiver lights up when optical synchronization is used) |
| HFT (ہارڈویئر فالٹ ٹولرنس) | 1 |
| کنٹرول آؤٹ پٹس (OSSD 1، OSSD 2) | PNP open-collector transistor / NPN open collector transistor (selectable)<PNP output selected>・Maximum source current : 350 mA・Applied voltage : Same as supply voltage(between control output and +V)・Residual voltage : 2 V or less (source current 350 mA)(excluding voltage drop due to cable)・Leakage current : 0.2 mA or less (including power OFF state)・Maximum load capacity : 2.2 μF・Load wiring resistance : 3 Ω or less<NPN output selected>・Maximum sink current : 350 mA・Applied voltage : Same as supply voltage(between control output and 0 V)・Residual voltage : 2 V or less (sink current 350 mA)(excluding voltage drop due to cable)・Leakage current : 0.2 mA or less (including power OFF state)・Maximum load capacity : 2.2 μF・Load wiring resistance : 3 Ω or less |
| مداخلت کی روک تھام کی تقریب | <Not connected in series/parallel>・Line synchronization : 2 units or less (auto)・Optical synchronization : 2 units or less (selectable by DIP switch)<Connected in series/parallel>・Series connection : 5 units or less (total number of beam channels 256 or less)・Parallel connection : 3 units or less (total number of beam channels 192 or less)(Note)・Series / parallel connection mixed : 5 units or less (total number of beam channels 144 or less)(Note)(Note): The setting can be changed when the SF4D-TM1 (optional) and Configurator Light Curtain setting software are used. |
| قابل اطلاق معیارات: شمالی امریکہ | ANSI/UL 61496-1/2 (Type 4),CAN/CSA C22.2 No.14, CAN/CSA E61496-1/2 |
| بیرونی آلہ کی نگرانی کی تقریب | Incorporated (8-core cable or 12-core cable) |
| وزن (ایمیٹر اور وصول کنندہ کا کل) | 890g approx. |
| قابل اطلاق ضوابط اور سرٹیفیکیشن | CE Marking (Machinery Directive, EMC Directive, RoHS Directive) , UKCA Marking (Machinery Regulations, EMC Regulations, RoHS Regulations), TÜV SÜD certification (U.S.A., Canada), OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06, Korea KCs mark |
| معاون پیداوار (AUX) (غیر حفاظتی پیداوار) | PNP open-collector transistor / NPN open collector transistor (selectable)<PNP output selected>・Maximum source current : 60 mA・Applied voltage : Same as supply voltage(between auxiliary output and +V)・Residual voltage : 2 V or less (source current 60 mA)(excluding voltage drop due to cable)・Leakage current : 0.2 mA or less (including power OFF state)<NPN output selected>・Maximum sink current : 60 mA・Applied voltage : Same as supply voltage(between auxiliary output and 0 V)・Residual voltage : 2 V or less (sink current 60 mA)(excluding voltage drop due to cable)・Leakage current : 0.2 mA or less (including power OFF state) |
| ماحولیاتی مزاحمت: محیطی نمی | 30 to 85 % RH, Storage : 30 to 95 % RH |
| ماحولیاتی مزاحمت: جھٹکا مزاحمت | 300 m/s2acceleration (30 G approx.) in X, Y, and Z directions three times eachMalfunction resistance 100 m/s2acceleration (10 G approx.) in X, Y, and Z directions 1,000 times each |
| قابل اطلاق معیار: بین الاقوامی معیار | IEC 61496-1/2 (Type 4), ISO 13849-1:2015 (Category 4, PLe), IEC 61508-1 to 3 (SIL3) |
| کنٹرول آؤٹ پٹ (OSSD 1، OSSD 2): رسپانس ٹائم | OFF response : 10 ms or less (Not connected in series / parallel), 18 ms or less (Connected in series / parallel)(Note 1)ON response : 50 ms or less (Note 2)(Note 3)(Note 1): For response times by number of beams, refer to the Control output (OSSD 1, OSSD 2) OFF response times.(Note 2): Because the control output (OSSD 1, OSSD 2) must be OFF for at least 80 ms, the ON response will be delayed more than 50 ms when the light blocked time is less than 30 ms.(Note 3): When optical synchronization is selected, if the beam axes of both the top end and bottom end are blocked, the ON response speed decreases by as much as 1 sec. |
| ماحولیاتی مزاحمت: محیطی درجہ حرارت | -10 to +55 ℃+14 to +131 ℉(No dew condensation or icing allowed), Storage : -25 to +60 ℃-13 to +140 ℉ |
| ماحولیاتی مزاحمت: تحفظ کی ڈگری | IP67, IP65 (IEC), NEMA Type 13 (NEMA 250) |
| ماحولیاتی مزاحمت: کمپن مزاحمت | 10 to 55 Hz, 0.75 mm0.030 indouble amplitude in X, Y, and Z directions for two hours eachMalfunction resistance 10 to 55 Hz, 0.75 mm0.030 indouble amplitude in X, Y, and Z directions twenty times each |
| ماحولیاتی مزاحمت: موصلیت مزاحمت | 20 MΩ, or more, with 500 V DC megger, between all supply terminals connected together and enclosure |
| کنٹرول آؤٹ پٹس (OSSD 1، OSSD 2): آپریشن موڈ | ON when all beams are received, OFF when one or more beams are blocked(Also OFF when internal sensor error or synchronization signal error occurs)(Note): The setting can be changed when the SF4D-TM1 (optional) and Configurator Light Curtain setting software are used. |
| کنٹرول آؤٹ پٹس (OSSD1، OSSD2): پروٹیکشن سرکٹ | Incorporated |
| ماحولیاتی مزاحمت: وولٹیج کے خلاف مزاحمت | 1,000 V AC for one minute, between all supply terminals connected together and enclosure |
| معاون پیداوار (AUX) (غیر حفاظتی پیداوار): جوابی وقت | OFF response : 60 ms or less, ON response : 60 ms or less |
| معاون آؤٹ پٹ (AUX)(غیر حفاظتی آؤٹ پٹ): آپریشن موڈ | Control output ON : OFF, Control output OFF : ON(Note): The setting can be changed when the SF4D-TM1 (optional) and Configurator Light Curtain setting software are used. |
| معاون پیداوار (AUX)(غیر حفاظتی پیداوار): تحفظ سرکٹ | Incorporated |
| حفاظتی اونچائی: چینی پریس مشین کے لیے حفاظتی سامان کے طور پر استعمال کرتے وقت | 380 mm14.961 in(Note): When using as a safety device for a press machine in China, the length from the center of the first beam channel to the center of the last beam channel become to be protective height. |
تکنیکی تفصیلات اور کارکردگی کے ڈیٹا
انسٹالیشن اور آپریشن گائیڈ