| پیرامیٹر | قیمت |
|---|---|
| آئٹم | Specifications |
| پی ایف ایچ ڈی | Refer to the following table(Note: (Probability of dangerous failure per hour) depends on number of single beam sensorST4-A□connected to controller.) |
| ایم ٹی ٹی ایف ڈی | More than 100 years (Note:Mean time to dangerous failure (in years)) |
| وزن | Net weight: 180 g approxGross weight: 390 g approx |
| تفصیلات | Controller |
| پروڈکٹ | Compact Type 4 Safety Beam Sensor |
| مواد | Enclosure: ABS |
| پارٹ نمبر | ST4-C11 |
| پروڈکٹ کا نام | Compact Type 4 Safety Beam Sensor ST4 |
| وائرنگ کیبل | Terminal block connector: 0.2 to 1.5 mm2 |
| پاور وولٹیج | 24 V DC +10-15 % Ripple P-P 10 % or less |
| جوابی وقت | OFF response: 25 ms or lessON response: 90 ms or less (auto reset) / 140 ms or less (manual reset) |
| پروڈکٹ نمبر | ST4-C11 |
| معاون پیداوار | PNP open-collector transistor / NPN open-collector transistor (Set using output polarity selection switch)ST4-C11: one outputST4-C12EX: four outputs[PNP output]Maximum source current: 100 mAApplied voltage: same as the supply voltage (between auxiliary output and +V)Residual voltage: 2.5 V or less (at 100 mA source current)[NPN output]Maximum sink current: 100 mAApplied voltage: same as the supply voltage (between auxiliary output and 0 V)Residual voltage: 2.0 V or less (at 100 mA sink current)(Note) If the total current of the control outputs (OSSD1, OSSD2), auxiliary outputs, and muting lamp output exceeds 400 mA, the wiring resistance between the controller and the power supply should be 1 Ohm or less. In addition, if the total current is 400 mA or less, the wiring resistance between the controller and the power supply should be 2 Ohm or less. |
| لیمپ آؤٹ پٹ کو خاموش کرنا | -(Note) If the total current of the control outputs (OSSD1, OSSD2), auxiliary outputs, and muting lamp output exceeds 400 mA, the wiring resistance between the controller and the power supply should be 1 Ohm or less. In addition, if the total current is 400 mA or less, the wiring resistance between the controller and the power supply should be 2 Ohm or less. |
| کنکشن ٹرمینل | Detachable spring-cage terminal |
| موجودہ کھپت | 100 mA or less (excluding sensor head ST4-Ax) |
| قابل اطلاق معیارات | IEC 61496-1/2 (JIS B 9704-1/2 / UL 61496-1/2) (Type 4), ISO 13849-1:2015 (Category 4, PLe), JIS B 9705-1 (Category 4), IEC 61508-1 to 3 (SIL3), IEC 62061 (SIL3), JIS C 0508-1 to 3 (SIL3), UL 1998, OSHA 1910.212, OSHA 1910.217 (C), ANSI B11.1 to B11.19, ANSI/RIA R15.06, ANSI/ISA S84.01 (SIL3)(Note) Complies with those standards only when the controller is used in combination with the sensor head ST4-x. |
| قابل اطلاق سینسر ہیڈ | ST4-Ax |
| CE نشان زد ہدایت کی تعمیل | Machinery Directive, EMC Directive, RoHS Directive |
| معاون آؤٹ پٹس: آپریشن موڈ | OFF when all beams of the connected ST4-Axs are receivedON when one or more beams of the connected ST4-Axs are interrupted |
| کنٹرول آؤٹ پٹس (OSSD 1، OSSD 2) | PNP open-collector transistor / NPN open-collector transistor Dual output x 1 system (Set using output polarity selection switch)[PNP output]Maximum source current: 200 mAApplied voltage: same as the supply voltage (between control output and +V)Residual voltage: 2.5 V or less (at 200 mA source current)Leakage current: 200 micro A or less (including power OFF condition)Maximum load capacity: 1 micro F (from no-load to max. source current)Load wiring resistance: 3 Ohm or less (between control output and load)[NPN output]Maximum sink current: 200 mAApplied voltage: same as the supply voltage (between control output and 0 V)Residual voltage: 2.0 V or less (at 200 mA sink current)Leakage current: 200 micro A or less (including power OFF condition)Maximum load capacity: 1 micro F (from no-load to max. sink current)Load wiring resistance: 3 Ohm or less (between control output and load)(Note) If the total current of the control outputs (OSSD1, OSSD2), auxiliary outputs, and muting lamp output exceeds 400 mA, the wiring resistance between the controller and the power supply should be 1 Ohm or less. In addition, if the total current is 400 mA or less, the wiring resistance between the controller and the power supply should be 2 Ohm or less. |
| معاون آؤٹ پٹس: پروٹیکشن سرکٹ | Incorporated |
| خاموش لیمپ آؤٹ پٹ: پروٹیکشن سرکٹ | Incorporated |
| ماحولیاتی مزاحمت: محیطی نمی | 30 to 85 % RH, Storage: 30 to 95 % RH |
| ماحولیاتی مزاحمت: جھٹکا مزاحمت | 300 m/s2acceleration in X, Y and Z directions three times each |
| ماحولیاتی مزاحمت: محیطی درجہ حرارت | -10 to +55 ℃+14 to +131℉(No dew condensation or icing allowed),Storage: -25 to +70 ℃-13 to +158℉ |
| ماحولیاتی مزاحمت: تحفظ کی ڈگری | Enclosure: IP40 (IEC)Terminal: IP20 (IEC) |
| ماحولیاتی مزاحمت: کمپن مزاحمت | 10 to 55 Hz frequency, 0.75 mm0.030 indouble amplitude or maximum acceleration 90 m/s2 in X, Y and Z directions for two hours each< |
| ماحولیاتی مزاحمت: موصلیت مزاحمت | 20 MOhm or more with 500 V DC mega between all supply terminals connected together and enclosure |
| کنٹرول آؤٹ پٹس (OSSD 1، OSSD 2): آپریشن موڈ | ON when all beams of the connected ST4-Axs are receivedOFF when one or more beams of the connected ST4-Axs are interruptedOFF during lockout |
| قابل اطلاق سینسر ہیڈ: نہیں سیریز کے رابطوں کا | Interference prevention possible when up to a maximum of 6 sets are connected(When the maximum of 3 controllers are connected together, interference prevention is possible for up to 18 sets) |
| کنٹرول آؤٹ پٹس (OSSD1، OSSD2): پروٹیکشن سرکٹ | Incorporated |
| ماحولیاتی مزاحمت: وولٹیج کے خلاف مزاحمت | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
تکنیکی تفصیلات اور کارکردگی کے ڈیٹا
انسٹالیشن اور آپریشن گائیڈ